November 2021 saw the release of the updated application of the National Building Regulations SANS 10400-XA: 2021 Ed 2 Energy usage in buildings, this follows on the original regulations promulgated in November 2011. The new regulations make it mandatory to specify thermal insulation in buildings based on their occupancy class as stated in regulations XA1, XA2 and XA3.
Energy zones
The original climate zones from the original regulations have been replaced with energy zones. There are 7 energy zones across South Africa and these were determined by the heating and cooling energy required to regulate the internal comfort levels of buildings. The explanation of each energy zone can be identified using the legend on the map:
Complete our enquiry form if you require more information
Energy Zones | 1-7 | 5H |
---|---|---|
Minimum Thermal Resistance required – Total R-value m²K/W | 3.7 | 2.7 |
- Total R-value of roof tiles & standard ceiling board m²K/W * | 0.35 | 0.35 |
- RadenShield Ecosential R-vale contribution m²K/W | 1.52 | 1.52 |
Remaining R-vale required from other insulation materials m²K/W | 1.83 | 0.83 |
* Source: TIPSASA (www.tipsasa.co.za)